6 resultados para 610

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present thesis a thourough multiwavelength analysis of a number of galaxy clusters known to be experiencing a merger event is presented. The bulk of the thesis consists in the analysis of deep radio observations of six merging clusters, which host extended radio emission on the cluster scale. A composite optical and X–ray analysis is performed in order to obtain a detailed and comprehensive picture of the cluster dynamics and possibly derive hints about the properties of the ongoing merger, such as the involved mass ratio, geometry and time scale. The combination of the high quality radio, optical and X–ray data allows us to investigate the implications of the ongoing merger for the cluster radio properties, focusing on the phenomenon of cluster scale diffuse radio sources, known as radio halos and relics. A total number of six merging clusters was selected for the present study: A3562, A697, A209, A521, RXCJ 1314.4–2515 and RXCJ 2003.5–2323. All of them were known, or suspected, to possess extended radio emission on the cluster scale, in the form of a radio halo and/or a relic. High sensitivity radio observations were carried out for all clusters using the Giant Metrewave Radio Telescope (GMRT) at low frequency (i.e. ≤ 610 MHz), in order to test the presence of a diffuse radio source and/or analyse in detail the properties of the hosted extended radio emission. For three clusters, the GMRT information was combined with higher frequency data from Very Large Array (VLA) observations. A re–analysis of the optical and X–ray data available in the public archives was carried out for all sources. Propriety deep XMM–Newton and Chandra observations were used to investigate the merger dynamics in A3562. Thanks to our multiwavelength analysis, we were able to confirm the existence of a radio halo and/or a relic in all clusters, and to connect their properties and origin to the reconstructed merging scenario for most of the investigated cases. • The existence of a small size and low power radio halo in A3562 was successfully explained in the theoretical framework of the particle re–acceleration model for the origin of radio halos, which invokes the re–acceleration of pre–existing relativistic electrons in the intracluster medium by merger–driven turbulence. • A giant radio halo was found in the massive galaxy cluster A209, which has likely undergone a past major merger and is currently experiencing a new merging process in a direction roughly orthogonal to the old merger axis. A giant radio halo was also detected in A697, whose optical and X–ray properties may be suggestive of a strong merger event along the line of sight. Given the cluster mass and the kind of merger, the existence of a giant radio halo in both clusters is expected in the framework of the re–acceleration scenario. • A radio relic was detected at the outskirts of A521, a highly dynamically disturbed cluster which is accreting a number of small mass concentrations. A possible explanation for its origin requires the presence of a merger–driven shock front at the location of the source. The spectral properties of the relic may support such interpretation and require a Mach number M < ∼ 3 for the shock. • The galaxy cluster RXCJ 1314.4–2515 is exceptional and unique in hosting two peripheral relic sources, extending on the Mpc scale, and a central small size radio halo. The existence of these sources requires the presence of an ongoing energetic merger. Our combined optical and X–ray investigation suggests that a strong merging process between two or more massive subclumps may be ongoing in this cluster. Thanks to forthcoming optical and X–ray observations, we will reconstruct in detail the merger dynamics and derive its energetics, to be related to the energy necessary for the particle re–acceleration in this cluster. • Finally, RXCJ 2003.5–2323 was found to possess a giant radio halo. This source is among the largest, most powerful and most distant (z=0.317) halos imaged so far. Unlike other radio halos, it shows a very peculiar morphology with bright clumps and filaments of emission, whose origin might be related to the relatively high redshift of the hosting cluster. Although very little optical and X–ray information is available about the cluster dynamical stage, the results of our optical analysis suggest the presence of two massive substructures which may be interacting with the cluster. Forthcoming observations in the optical and X–ray bands will allow us to confirm the expected high merging activity in this cluster. Throughout the present thesis a cosmology with H0 = 70 km s−1 Mpc−1, m=0.3 and =0.7 is assumed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. Portal pressure is measured invasively as Hepatic Venous Pressure Gradient (HVPG) in the angiography room. Liver stiffness measured by Fibroscan was shown to correlate with HVPG values below 12 mmHg. This is not surprising, since in cirrhosis the increase of portal pressure is not directly linked with liver fibrosis and consequently to liver stiffness. We hypothesized that, given the spleen’s privileged location upstream to the whole portal system, splenic stiffness could provide relevant information about portal pressure. Aim of the study was to assess the relationship between liver and spleen stiffness measured by Virtual Touch™ (ARFI) and HVPG in cirrhotic patients. METHODS. 40 consecutive patients (30 males, mean age 62y, mean BMI=26, mean Child-Pugh A6, mean platelet count=92.000/mmc, 19 HCV+, 7 with ascites) underwent to ARFI stiffness measurement (10 valid measurements in right liver lobe both surface and centre, left lobe and 20 in the spleen) and HPVG, blindly to each other. Median ARFI values of 10 samplings on every liver area and of 20 samplings on spleen were calculated. RESULTS. Stiffness could be easily measured in all patients with ARFI, resulting a mean of 2,61±0,76, 2,5±0,62 and 2,55±0,66 m/sec in the liver areas and 3.3±0,5 m/s in the spleen. Median HPVG was 14 mmHg (range 5-27); 28 patients showed values ≥10 mmHg. A positive significant correlation was found between spleen stiffness and HPVG values (r=0.744, p<0.001). No significant correlation was found between all liver stiffness and HVPG (p>0,05). AUROC was calculated to test spleen stiffness ability in discriminating patients with HVPG ≥10. AUROC = 0.911 was obtained, with sensitivity of 69% and specificity of 91% at a cut-off of 3.26 m/s. CONCLUSION. Spleen stiffness measurement with ARFI correlates with HVPG in patients with cirrhosis, with a potential of identifying patients with clinically significant portal hypertension.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this thesis, we have presented two deep 1.4 GHz and 345 MHz overlapping surveys of the Lockman Hole field taken with the Westerbork Synthesis Radio Telescope. We extracted a catalogue of ~6000 radio sources from the 1.4 GHz mosaic down to a flux limit of ~55 μJy and a catalogue of 334 radio sources down to a flux limit of ~4 mJy from the inner 7 sq. degree region of the 345 MHz image. The extracted catalogues were used to derive the source number counts at 1.4 GHz and at 345 MHz. The source counts were found to be fully consistent with previous determinations. In particular the 1.4 GHz source counts derived by the present sample provide one of the most statistically robust determinations in the flux range 0.1 < S < 1 mJy. During the commissioning program of the LOFAR telescope, the Lockman Hole field was observed at 58 MHz and 150 MHz. The 150 MHz LOFAR observation is particularly relevant as it allowed us to obtain the first LOFAR flux calibrated high resolution image of a deep field. From this image we extracted a preliminary source catalogue down to a flux limit of ~15 mJy (~10σ), that can be considered complete down to 20‒30 mJy. A spectral index study of the mJy sources in the Lockman Hole region, was performed using the available catalogues ( 1.4 GHz, 345 MHz and 150 MHz) and a deep 610 MHz source catalogue available from the literature (Garn et al. 2008, 2010).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Clinical trials have demonstrated that selected secondary prevention medications for patients after acute myocardial infarction (AMI) reduce mortality. Yet, these medications are generally underprescribed in daily practice, and older people are often absent from drug trials. Objectives: To examine the relationship between adherence to evidence-based (EB) drugs and post-AMI mortality, focusing on the effects of single therapy and polytherapy in very old patients (≥80 years) compared with elderly and adults (<80 years). Methods: Patients hospitalised for AMI between 01/01/2008 and 30/06/2011 and resident in the Local Health Authority of Bologna were followed up until 31/12/2011. Medication adherence was calculated as the proportion of days covered for filled prescriptions of angiotensin-converting enzyme inhibitors (ACEIs)/angiotensin receptor blockers (ARBs), β-blockers, antiplatelet drugs, and statins. We adopted a risk set sampling method, and the adjusted relationship between medication adherence (PDC≥75%) and mortality was investigated using conditional multiple logistic regression. Results: The study population comprised 4861 patients. During a median follow-up of 2.8 years, 1116 deaths (23.0%) were observed. Adherence to the 4 EB drugs was 7.1%, while nonadherence to any of the drugs was 19.7%. For both patients aged ≥80 years and those aged <80 years, rate ratios of death linearly decreased as the number of EB drugs taken increased. There was a significant inverse relationship between adherence to each of 4 medications and mortality, although its magnitude was higher for ACEIs/ARBs (adj. rate ratio=0.60, 95%CI=0.52–0.69) and statins (0.60, 0.50–0.72), and lower for β-blockers (0.75, 0.61–0.92) and antiplatelet drugs (0.73, 0.63–0.84). Conclusions: The beneficial effect of EB polytherapy on long-term mortality following AMI is evident also in nontrial older populations. Given that adherence to combination therapies is largely suboptimal, the implementation of strategies and initiatives to increase the use of post-AMI secondary preventive medications in old patients is crucial.